An introduction to multivariate calibration and analysis

Authors
Kenneth R. Beebe and Bruce R. Kowalski
Published
1987
DOI
10.1021/ac00144a001
Citation
Beebe and Kowalski: "An introduction to multivariate calibration and analysis", Analytical Chemistry, 59, 1007A-1017A, 1987.
Abstract
The advent of the laboratory computer has allowed analytical chemists to col- lect enormous amounts of data on a wide variety of problems of interest. With this ability, however, has come the realization that more data does not necessarily mean more information. One can collect reams of computer out- put without knowing anything more about the system under investigation. Only when theda t a a r e int e rpr e t edand put to use do they become valuable to the chemist and t o society in general: thendata become information. For this reason, data analysis methods that can handle large quantities of data are be- comine a necessitv for the nracticine the awareness of the need for moreso- phisticated techniques grows. Howev- er, widespread use of the full set of ana- lytical tools will be realized only when the analyst is familiar with the general goals and advantages of the methods. a n y situation where multiple measure- menta are acquired. One example of a n analytical prob- lem solved by near-IR reflectance anal- ysis is the estimation of the protein and moisture content of wheat samnles. As ~ introduction to the area of multivariate anal- yses known as multivariate calibration. Our goal is to give the chemist insight into the workings of a collection of statistical techniques and to enable him or her to judge the appropriateness of the techniques for an application of interest. The list of methods described is by no means a complete representation of those tha t can he applied to multivari ste data. Also, we do not compare the results obtained using one method over another; instead, we describe the methods in the line of a tutorial. For this reason, the examples chosen illustrate how the methods work rather than with many analytical methois, this procedure consists of two phases: cali bration and prediction. T h e chemist begins by constructing a data matrix (R) from the instrument responses a t selected wavelengths for a given set of calibration samples. I n the case of near-IR reflectance analysis, the R ma- trix can be constructed from the loga- rithmic reflectances (log(l/ref)) or from some other combination of reflec- tances obtained a t the various wave- lengths ( 4 ) . A matrix of concentration values (C) is then formed using inde- pendent or referee methods such as Kjeldahl nitrogen analysis for protein determination and oven-drvine . - for the compareamony them. The threemulti- variate methods that will be discussed determination of moisture content. The goal of the calibration Dhase is to are multiple linear regression (MLR), principal component regression (PCR), and partial least squares (PLS). MLR, a n extension of ordinary least squares, is the easiest to understand and also the most commonly used; PCR and PLS have yet t o achieve widespread acceptance in chemistry.
Tags